Cascade

The Cascade controller offers automatic start and stop control with easy configuration for a broad number of applications.

This auto-start controller is designed to fit any engine-driven application requiring a simple and robust automatic start and stop sequence. Pumps, compressors, grinders, power units and generators are just a few of the industrial applications for the controller. The Cascade controller is fully compatible with all major engine types. Whether you are running mechanical or J1939 engines, the controller will work with your application. The Cascade CD101 controller can also be used to replace legacy ASM150, ASM160 and ASM170 controllers.

Power input: 9-35VDC continuous - operates during total blackout for 2 seconds minimum.

Power consumption: Sleep Mode (Manual): 1mA typical; Sleep Mode (Automatic): 4mA typical.

Running Mode (Manual): 20mA typical; Running

Mode (Automatic): 24mA typical.

Operating/Storage temperature: -40 to 85°C; (-40 to 185°F).

Humidity: 0-100%, non-condensing.

Housing: UV stabilized black polycarbonate and epoxy encapsulation. Weather tight and includes sealing gasket to keep moisture and debris out of enclosure. Properly mounted controller will maintain NEMA4 / IP65 rating of enclosure.

Vibration: Rated to 6G.

Impact: Rated to 10G.

Inputs: Dedicated digital inputs for low oil pressure, high engine temperature, remote start, DC charge fail/Alternator fail. Two aux inputs are configurable for multiple functions.

Outputs: 7 – 4 auxiliary, configurable (1A DC protected). 3 dedicated outputs for Crank, Fuel/ECU, Alternator excitation.

Crank attempts: 3, 5, 10, Continuous.

Crank Rest: 5-60 seconds, adjustable.

Shutdown lockout time delay: 5, 10, 15, 20, 25, 30 seconds.

Crank disconnect speed setting: Field settable 0-9999 RPM (16-60Hz AC freq input).

Overspeed/underspeed trip point setting: ±5 to 50% of nominal.

Speed sensing inputs: Magnetic pickup (5-120VAC RMS / 0-10 kHz) & AC frequency (30-600VAC RMS / 16-80 Hz).

CANbus interface: Directly reads engine speed, & engine status data* from SAE-J1939 enabled engines.

MODbus interface: In J1939 applications drives PVA series analog gages.

*Engine status data limited to low oil pressure, high engine temperature, “Wait to start” status, Warning & Fault lamp information, and communication error.

Service done right

Murphy by Enovation Service Network

Palmer Johnson's six-location factory-authorized service center network features:

  • Factory-trained technicians
  • Field service
  • Onsite troubleshooting and diagnostics
  • Unit removal and installation

For Murphy by Enovation service, call 1-800-341-4334.

Learn more

Madison, WI

Service Center

Service: (608) 834-5206

1835 Haynes Dr
Sun Prairie, WI 53590

Contact

Dallas, TX

Service Center

Service: (817) 505-2430

608 112th St
Arlington, TX 76011

Contact

Denver, CO

Service Dealer

Service: (720) 724-0033

5151 E 56th Ave
Commerce City, CO 80022

Contact

Kansas City, KS

Service Center

Service: (913) 202-6944

15360 South Mahaffie St
Olathe, KS 66062

Contact

Los Angeles, CA

Service Center

Service: (562) 356-1590

12020 Bloomfield Ave
Santa Fe Springs, CA 90670

Contact

Oklahoma City, OK

Warehouse

Sales: (800) 341-4334

Oklahoma City, OK 73128

Contact

Phoenix, AZ

Service Dealer

Service: (602) 253-0214

2401 S. 19th Street
Phoenix, AZ 85034

Contact

San Francisco, CA

Service Dealer

Service: (510) 342-2212

1930 W Winton Ave #14
Hayward, CA 94545

Contact

St. Louis, MO

Service Center

Service: (636) 203-9811

578 Rudder Rd
Fenton, MO 63026

Contact

Philadelphia, PA

Service Dealer

Service: (215) 822-8300

159 Discovery Dr
Colmar, PA 18915

Contact

Fort Myers, FL

Service Dealer

Service: (239) 693-7477

4821 Waycross Road
Fort Myers, FL

Contact

Odessa,

Service Center

Service: (432) 287-1015

By Appointment Only

Contact

Vancouver, British Columbia

Service Center

Service: (604) 879-6731

6741 Cariboo Rd Unit 205
Burnaby, British Columbia V3N 4A3

Contact

Edmonton, Alberta

Service Center

Service: (780) 434-9578

3804 53rd Ave NW
Edmonton, Alberta T6B 3N7

Contact

Seattle, WA

Service Center

Service: (425) 251-3434

1710 136th Ave E
Sumner, WA 98390

Contact

RECON Equipment Center, WI

Service Center

Service: (608) 834-5220

1828 Haynes Dr
Sun Prairie, WI 53590

Contact
Map of Palmer Johnson Power Systems locations