RP75

Features:

■ Pulls Injection Pump or Air Intake Shut-off Lever
■ 30 lbf (133 N) Operating Force
■ Models Available for 12 or 24 Volt Systems
■ Operates on Signal from SWICHGAGE® Installed on the Engine or Driven Equipment

Contact Us

Power Input: 6 to 28 VDC.

Power Consumption Standby: <1 mA.Operating Force: 30 lbf (133 N) maximum, 10 lbf (44 N) minimum.

Coil Voltage: Specify 12 or 24 VDC.

Coil Resistance:
RP75-12: 32.2 ohms.
RP75-24: 129.8 ohms.

Length of Travel: 1-7/8 in. (48 mm).

Control Linkage
Cable: 4ft. (1.22 m); Optional 8 ft. (2.43 m) or 12 ft. (3.65 m) available.
Chain (optional): 30 in. (762 mm).